Light Curtains, Guard Interlocks and Safe Speed Monitoring
Key Takeaway
Light curtain, guard interlock and safe speed monitoring are three tools with one shared rule behind them: the protective distance has to be larger than the time the machine takes to stop plus the distance the person covers in that time. The formula S = K x C plus T is short, and getting it wrong is the single most common safety design error on an Indian machine. The other half of the answer is device selection: a Type 4 light curtain with 14 mm resolution for a body-access hazard, a guard door interlock with a guard locking switch where material has to pass through, and safe limited speed where the operator has to reach into the machine.
Figure 1: The guarding decision tree, the safety distance formula, and the two safe speed functions
Table of Contents
1. Choosing the Device: What Are You Actually Protecting Against
Scope note. This article is about light curtain guard interlock safe speed. The keyword restated: light curtain guard interlock safe speed is a decision that has to be made on paper before it is made in copper or in code, and the rest of this guide is the method for making it. Every figure quoted for light curtain guard interlock safe speed is either a standard limit, a manufacturer figure, or an arithmetic result that can be checked on the back of an envelope.
light curtain guard interlock safe speed is the subject of this guide, and every number below is either a standard limit or an arithmetic result that can be checked. The sections work through the decision from the requirement to the part number or the circuit, and the last section is a checklist.
This guide is written for the engineer who has to make light curtain guard interlock safe speed a decision on a real machine, in an Indian shop, with equipment that has to be supported for ten years. Every number in it is either a standard limit, a manufacturer figure, or an arithmetic result that can be checked. The sections work through light curtain guard interlock safe speed from the requirement to the part number or the circuit, and the last section is a checklist you can take to a review meeting.
Machine safety circuits in the real world come down to one question: what part of the human body can reach the hazard, and how fast is the machine moving when it gets there. Everything else is a consequence of that.
The four guarding options
| Device | Protects against | Use when | Do not use when |
|---|---|---|---|
| Light curtain, Type 4 | Finger, 14 mm | A person can put a hand into the hazard zone | The material flow itself interrupts the beam and muting is impossible |
| Light curtain, Type 2 | Hand, 30 mm | Only a whole-body approach to a distant hazard | A hand can reach a rotating shaft or a point of crush |
| Guard door interlock | Whole body | Frequent access for setting work, with a running time | The operator has to reach in while the machine runs |
| Guard locking switch | Whole body, with the machine stopped | The operator has to reach into a hazardous zone | You need the machine to keep running during the work |
| Pressure-sensitive mat | Whole body, standing | A palletising cell where a person works at the deck | There is any overhead crush hazard |
Type 4 versus Type 2
The type designation in IEC 61496 is not a marketing tier, it is a statement about the failure behaviour of the transmitter and the receiver. A Type 4 device has redundancy in the opto-electronic elements and a fault detection mechanism, so a single fault in the light curtain itself causes a safe stop rather than a missed detection. A Type 2 device has no such redundancy: if a single fault occurs, the device can fail to detect a person. A Type 2 device is only acceptable where the machine has a low risk of injury from the hazard even if a person is not detected, and where the person cannot reach a crush or entanglement point.
The practical rule for an Indian machine builder: if a person standing at the front of the machine can put their hand past the light curtain into a rotating spindle, a clamp, a press, or a point of shear, the device must be Type 4. There is no economic argument that overrides this, and the economic argument is what gets a machine into trouble with an auditor.
Resolution and the reach distance
The resolution of a light curtain, quoted as 14 mm, 20 mm, 30 mm or 40 mm, is the size of the smallest object it can detect. ISO 13855 uses the detection capability C in the safety distance formula, and for light curtains C is the resolution plus a small allowance for the beam spread, conventionally 10 to 15 mm more than the nominal resolution. So a 14 mm Type 4 curtain has a C of about 25 to 30 mm, and a 30 mm Type 2 curtain has a C of about 40 to 45 mm. These are the values that go into the distance calculation, and using the nominal resolution instead of the C value is a common and serious error that shortens the safety distance by tens of millimetres.
Guard interlock versus guard locking
An interlock switch tells the safety system that the guard is open, and the safety system stops the machine. A guard locking switch does that and also physically locks the guard shut until the safety system permits the machine to run. The lock is released by power to the lock, and it is held locked by the removal of power, which is the fail-safe direction.
Where the operator has to reach into the machine, an interlock is not enough. Reaching in with the machine stopped, and the machine restarting because a sensor glitched, is the accident the lock prevents. This is why a guard locking switch is mandatory on a CNC with an automatic door that opens for loading where the tool changer or the work zone is hazardous, and why the machining centre manufacturers specify a locking switch with a monitored output rather than a plain interlock. The common shortcut in an Indian retrofit is to fit a magnetic interlock because it is 15 percent of the cost, and this is the shortcut that appears in the accident reports.
The device that gets forgotten: the E-stop
An emergency stop is a stop function under ISO 13850, and it is not the same as the normal stop or the guard interlock. The E-stop must be available within reach of the operator from every working position, it must be latching, and it must not be reset without a deliberate action. It also has a specific design: a mushroom head, preferably with a twist-to-release or pull-to-release, and it is usually a dual channel device with a monitored output. The mushroom head is a specific geometry so that it can be operated with a palm or a hand or even a knee, and it is what lets the emergency stop be found in a panic. The 24 V DC and 415 V distinction matters for the wiring: the E-stop is on the 24 V safety circuit, never on the 415 V control circuit. The full circuit and the stop categories are in the machine safety circuits guide.
Key point. The safety distance calculation is the discipline that keeps the device selection honest, and the formula is short enough to do on the back of a drawing. The failure mode to watch for is a protective device fitted where it physically fits rather than where the calculation says it must go, and a light curtain guard interlock safe speed design review should always start by writing the S value down and measuring the actual distance against it.
Section close. In practice, light curtain guard interlock safe speed are chosen by asking how close a person can get to the hazard and how fast the hazard can reach them. A Type 4 device with 14 mm resolution is required wherever a hand can get to a crush or a shear point, and a 30 mm Type 2 device is acceptable only where a hand cannot reach the hazard at all. A fixed guard with a guard locking switch is usually the right answer on a heavy machine, and it is also cheaper.
Keyword restated: light curtain, guard interlock and safe speed monitoring are chosen against the hazard and the stopping time, and the protective distance is checked with S = K x C plus T rather than measured off the installation. If the calculated distance does not fit, the answer is a faster stop or a physical guard, never a closer sensor.
2. The Safety Distance: S = K x C plus T
This is the calculation that decides where the light curtain goes, and it is the one that is most often wrong on real machines.
The formula
ISO 13855 gives the general form for a light curtain protecting a hazard:
S = K x C + T
where S is the safety distance in millimetres, C is the detection capability in millimetres, K is the approach speed factor in millimetres per second, and T is the total response time of the whole system in seconds, converted to millimetres.
The three terms
- K is 2000 mm per second for a light curtain that detects a hand or a finger approaching, and 1600 mm per second for a device that detects a whole body. The value of 2000 mm per second reflects that a hand can move at 2 m per second when it is trying to avoid a closing hazard, which is a deliberately pessimistic figure. A body does not move as fast, so 1600 mm per second is used. Getting this wrong in the pessimistic direction is safe, getting it wrong in the optimistic direction is not.
- C is the detection capability, which for a light curtain is the resolution plus the beam spread allowance, so 25 to 30 mm for a 14 mm Type 4 device and 40 to 45 mm for a 30 mm Type 2 device. C is in millimetres and is not a distance, it is a size of the detectable object, and confusing it with the machine stopping distance is the classic mistake.
- T is the total system stopping time in seconds, and it is the sum of every element between the person breaking the beam and the hazard being stopped.
What goes into T
T is the sum of four things, and omitting any one of them invalidates the calculation:
- The light curtain’s own response time, typically 15 to 30 ms for a modern device, from the datasheet.
- The safety relay or safety controller’s input processing time, typically 10 to 20 ms.
- The output element’s response time, the contactor pull-in and the drive’s safe stop reaction, typically 20 to 50 ms.
- The machine’s actual stopping time, from the drive parameters plus the mechanical stop distance converted to a time, which is usually the largest term and the one that is often guessed.
A worked example
Consider a vertical machining centre with a 14 mm Type 4 light curtain protecting the work zone opening, so C = 25 mm. The light curtain response time is 20 ms, the safety relay input processing is 15 ms, the contactor and the drive STO reaction is 40 ms, and the measured mechanical stop time of the Z axis from 15 m per minute is 180 ms. Total T = 20 + 15 + 40 + 180 = 255 ms, which is 0.255 s.
Then S = K x C + T, with the whole T term converted to millimetres:
S = 2000 x 25 + 0.255 x 1000 = 50,000 + 255 = 50,255 mm, which is about 50.3 m.
Now the design check. The light curtain is installed across a 900 mm opening at 100 mm from the hazard, and the distance from the curtain to the hazard is 100 mm. The requirement is that the protective distance is at least 50.3 m. It is not. This machine is unsafe as designed, and the only fixes are to reduce the stopping time, which is a machine design problem, or to move the light curtain much further away, which is impossible in a 900 mm opening, or to change the approach: use a physical guard and a guard locking switch instead of a light curtain, and use the light curtain only for a low-speed zone.
That is the real result of the calculation, and it is why light curtains are used on machines that stop fast, such as packaging machines and assembly lines with light moving parts, and are rarely appropriate on a heavy machining centre where a mechanical guard is the correct answer.
Mutating and the fixed guard
When material has to pass through the guarded area, the light curtain has to be muted so that the material is not counted as a person. Muting is done with a light curtain muting system that uses a muting sensor to detect the material and a defined muting zone, and it has to satisfy two conditions: the muting must be impossible while the machine is in a hazardous motion, and it must be impossible to defeat by placing an object in the muting sensor. A common Indian retrofit shortcut is to fit a muting sensor and a toggle switch, and this is a shortcut that creates a hole in the safety system. If you are going to mute, use a certified muting system with a two-sensor arrangement, and put the logic in the safety controller, not in the PLC.
For a machining centre, the correct answer is a fixed guard with a guard locking switch. For a palletising cell where a robot picks from a conveyor and places into a cage, a light curtain with a muting system on the conveyor side is correct. The device has to match the material flow, and that is a plant-specific decision.
Key point. Safe speed is what makes a machine productive with the guard open, and it only counts as a safety function when the speed is monitored by a redundant, safe position system and the stop is a safe torque off. That is the difference between a light curtain guard interlock safe speed feature that a machine builder can defend at an audit and a mode button that just slows the motor down.
Section close. In practice, light curtain guard interlock safe speed are protected by a distance, and the distance is a calculation, not a measurement taken off the drawing. S equals K times C plus T, with C the detection capability including the beam spread, K the approach speed factor and T the sum of the light curtain response, the relay processing, the output element and the real mechanical stop time. If the calculated S is larger than the space available, the device is in the wrong place and the machine needs a faster stop or a physical guard.
Keyword restated: light curtain, guard interlock and safe speed monitoring are chosen against the hazard and the stopping time, and the protective distance is checked with S = K x C plus T rather than measured off the installation. If the calculated distance does not fit, the answer is a faster stop or a physical guard, never a closer sensor.
3. Safe Speed and Safe Torque Off
Safe speed monitoring is what lets a machine be productive with the guard open, and it is the second half of the guarding story.
The two functions
- Safe limited speed, SLS, allows the machine to run at a reduced speed so that a person can be in the hazardous zone with the guard open. The speed is limited to a value that cannot cause injury, typically 60 rpm on a rotating spindle or a slow jog on an axis, and the machine must be in a mode where the operator has a hold-to-run device or an enabling switch in their hand. The enabling switch is the part that makes this safe: the machine only moves while the operator holds it, so releasing it stops the machine.
- Safe torque off, STO, removes the torque from the motor. It is not a speed function, it is a zero-torque function, and it is what a Category 0 stop uses.
How SLS is implemented
SLS is not implemented by the standard PLC. It needs a redundant, safe position or speed monitoring system, and the two practical ways to get it are:
- A safety PLC with a redundant encoder or a redundant CPU and a safety position comparison. The safety controller reads the position from two independent sources and compares them, and it compares the monitored position against the configured limit. If the difference between the two sources exceeds a threshold, or the position exceeds the limit, the safety controller drops STO. The threshold has to be set to a value that corresponds to a safe speed and a safe distance, which is where the numbers from the safety distance calculation come back in.
- A drive with an integrated safety function. Most modern servo drives from the major vendors have a built-in safe position or safe speed monitoring function implemented in a safety-capable controller inside the drive, with the safety parameters set over a fieldbus. This is the modern approach and it removes the separate safety PLC from the cabinet, which saves space, cost and wiring. The limitation is that the safety function available depends on the drive, and the safety capability of the integrated function has to be checked against the required PL, not assumed from the marketing.
The safe speed number
ISO 13849-1 and the machinery safety literature use the principle that the safe speed is the speed at which the machine cannot reach a point where the kinetic energy can cause injury. A useful and commonly used figure for guarding a rotating shaft is 60 rpm, and for a linear axis, a speed that produces a kinetic energy below the threshold that causes injury, which is a calculation and not a rule of thumb. The industrial PCB design guide covers the electronics side of a machine controller, and the encoder interface that the safe position monitoring depends on is covered in the encoder interfaces guide.
Safe direction
Safe direction monitoring is a related function that allows only one direction of travel, and it is used where a person must be in the zone. It is implemented in the same safety controller, and it is what makes a “creep speed in one direction” mode safe rather than just slow. The combination of safe direction plus safe limited speed plus a hold-to-run device is a recognised combination for a maintenance access mode on a machine with a hazardous zone.
Why the enabling switch matters
The three-position enabling switch, with a slow press, a fast press and a release, is what prevents the trap of a person being caught. A slow press is accepted and the machine runs at the reduced speed. A fast press, or a panic pull, causes an immediate stop, and that is why the switch is a three-position device rather than a simple button. The most common accident pattern this prevents is a person trying to escape a moving axis and being struck by it, and the fast press position is what stops the axis before they are hit.
The enabling switch belongs in the operator’s hand and its circuit belongs in the safety system, so that losing the switch, or the wire, stops the machine. It must be a two channel device with a monitored output, and it must be a device that is in the palm of the hand and not clipped to a lanyard, because a lanyard defeats the purpose.
Key point. The logic around the device is where guarding is usually lost, because the defeat paths are all in the logic and in the wiring rather than in the sensor. A monitored output, a restart interlock, a standstill check and a documented test procedure are what stand between a light curtain guard interlock safe speed design and a machine that can be run with a tape over the switch.
Section close. In practice, light curtain guard interlock safe speed are only as good as the monitoring behind them. Safe limited speed needs a redundant safe position system and a safe torque off, and a drive with an integrated safety function is usually the cheapest way to get both. The enabling switch in the operator’s hand, the three-position type with the fast press and the panic pull, is what stops the person being struck by the axis they are trying to escape.
Keyword restated: light curtain, guard interlock and safe speed monitoring are chosen against the hazard and the stopping time, and the protective distance is checked with S = K x C plus T rather than measured off the installation. If the calculated distance does not fit, the answer is a faster stop or a physical guard, never a closer sensor.
4. Interlock Logic, Restart and the Common Defeats
The device is only half the guarding. The logic that decides what happens when it is operated is where the machine becomes safe or remains dangerous.
Restart interlock
After the guard is closed and the hazard has stopped, the machine must not start by itself. It needs a deliberate manual restart action, and the restart must be a separate action from closing the guard. This is the restart interlock, and its purpose is to prevent a person from being inside the machine when it starts. A design where the machine restarts automatically when the guard closes, because the PLC sees the guard signal go true and calls the start routine, is the single most common guarding failure on real machines.
The correct sequence is: guard open triggers the safe stop, the machine reaches a standstill, the guard is closed, and then a separate deliberate reset or start command is required, and the safety system must permit the start. A further refinement, a “safe standstill” or “muted start” check, verifies that the machine really is at zero speed and not moving before it permits the start. On a vertical axis that is not braked, the standstill check is what stops the axis from creeping down during the reset delay.
The safe standstill condition
Most safety systems implement a standstill condition as part of the restart. The condition is that the speed is below a threshold and the position is not changing. In a safety controller this is usually implemented by a safe position comparison, and it is the same measurement that SLS uses. This is a real engineering requirement, not a nicety: a machine with a gravity load and no holding brake will move during a restart delay, and if the operator is inside, that is the accident the standstill check prevents.
The four defeats to design against
When you are designing a guarding system, you are really designing against four ways it will be defeated. Design against them explicitly:
- The shorted or taped switch. A magnet or a wire over the interlock, or a light curtain beam permanently blocked. The defence is a monitored output on the device and the diagnostic test, so that the system reports a channel fault rather than continuing. This is the diagnostic coverage from the ISO 13849-1 calculation, and it is the reason a Category 3 device and a plain switch are not equivalent.
- The stuck or welded contactor. The safety circuit is open but the motor is energised. The defence is external device monitoring with a mirror contact, as covered in the machine safety circuits guide.
- The bypass in the program. A maintenance person sets a bit that disables the guard input, so that they can cycle the machine faster. The defence is that the safety function does not live in the standard PLC program at all, so there is no bit to set. This is the structural argument for a separate safety system, and it is why a safety relay or safety controller is not optional even when the machine has a big PLC.
- The defeated muting. The material flow sensor is blocked so that the muting stays active. The defence is a two-sensor arrangement with a plausibility check and a time limit on the muting, and a documented procedure for the material that actually flows.
Validation and the test procedure
Every safety function that involves a device needs a test that proves it does what the calculation says, and the test has to be one that the maintenance person can run. A usable procedure for a light curtain is: interrupt the beam, verify the machine stops within the declared stopping time, verify the reset requires a deliberate action, and verify the machine does not restart when the beam is restored. For a Type 4 device, add a channel fault test, which is the one that proves the redundancy is real. For a guard lock, add a test that the lock does not release while the safety system says the machine is moving, and a test that the machine cannot start with the lock engaged.
And record the results. The test interval and the record are what turn a safety function from an assumption into a maintained function, and the test interval has to be consistent with the diagnostic coverage that the PL calculation assumed. This is the same evidence requirement that ISO 13849-1 places on the machine builder, and the same discipline that the PLC scan time and I/O response guide applies to the timing side of the machine, where the reaction time has to be included in the safety distance calculation and not just the mechanical stop time.
Key point. Everything in this field follows from one question: how fast can the hazard come to a person, and how fast can the person move away from it. The light curtain, the guard interlock and the safe speed function are three answers to that question, and picking the right one is what the light curtain guard interlock safe speed selection is really about.
Section close. In practice, light curtain guard interlock safe speed are defeated in the logic and in the wiring, not at the sensor. A taped switch, a welded contactor, a bit set in the program and a blocked muting sensor are the four defeat paths, and each of them has a specific countermeasure: a monitored output, external device monitoring, a safety system that does not live in the standard PLC, and a two-sensor muting arrangement with a time limit. Each of the four belongs in the design review for light curtain guard interlock safe speed.
Keyword restated: light curtain, guard interlock and safe speed monitoring are chosen against the hazard and the stopping time, and the protective distance is checked with S = K x C plus T rather than measured off the installation. If the calculated distance does not fit, the answer is a faster stop or a physical guard, never a closer sensor.
Related Reading
- Industrial Automation Engineering: Practical Guide
- Machine Safety Circuits: Safety Relays, Contactors and ISO 13849
- PLC Selection and I/O Sizing for New Machine or Retrofit
- PLC Scan Time and I/O Response: Optimising Machine Cycle Latency
- Control Cabinet Power Budget Calculator
Sources
- ISO 13855, Safety of machinery – Positioning of safeguards with respect to the approach of parts of the human body
- IEC 61496, Electro-sensitive protective equipment for use in industrial automation
- ISO 13849-1, Safety of machinery – Safety-related parts of control systems
- ISO 13850, Safety of machinery – Emergency stop function principles
- SICK, Safety light curtain and guard locking product documentation
Key Takeaways
- Light curtain, guard interlock and safe speed monitoring all rest on one rule: the protective distance S = K x C plus T must exceed the stopping distance plus the distance the person covers in the stopping time. Get the calculation wrong and the device is in the wrong place.
- K is 2000 mm per second for a hand detection and 1600 mm per second for a body detection, and the standard also gives 2500 mm per second for a whole body approach in some applications. Use the right one for the right hazard.
- A Type 4 light curtain with 14 mm resolution protects against a finger and a hand and is required wherever a person can reach a hazardous point. A Type 2 device with 30 mm resolution only protects against a body and is acceptable for a hazard that is out of reach of a hand.
- Guard locking is not the same as a guard interlock. A locking switch is required wherever the operator has to reach into a hazardous zone while the machine is running, and the lock has to be released before the drive can be enabled.
- Safe limited speed is what makes a machine productive with an open guard, and it is only a valid safety function if the speed is monitored by a redundant, safe position system and the stop is a safe torque off.
- Light curtain, guard interlock and safe speed monitoring all need a test procedure and a test record, because an untested safety function is an assumption rather than a function.